{"product_id":"superfoil-sftv","title":"SuperFOIL SFTV","description":"\u003ch1 data-end=\"593\" data-start=\"507\"\u003e\u003cstrong data-end=\"593\" data-start=\"509\"\u003eSuperFOIL SFTV Reflective Vapour Control Layer – 2-in-1 Radiant Barrier Membrane\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp data-end=\"952\" data-start=\"595\"\u003eSuperFOIL SFTV is a \u003cstrong data-end=\"688\" data-start=\"615\"\u003ereflective vapour control layer (VCL) combined with a radiant barrier\u003c\/strong\u003e, designed to improve thermal performance and condensation control in \u003cstrong data-end=\"786\" data-start=\"758\"\u003eroofs, walls, and floors\u003c\/strong\u003e.\u003cbr data-end=\"790\" data-start=\"787\"\u003eWith an ultra-thin profile of \u003cstrong data-end=\"838\" data-start=\"820\"\u003eless than 1 mm\u003c\/strong\u003e, SFTV provides an efficient way to enhance insulation performance when used alongside other insulation materials.\u003c\/p\u003e\n\u003cp data-end=\"1144\" data-start=\"954\"\u003eSFTV is suitable for \u003cstrong data-end=\"1045\" data-start=\"975\"\u003enew builds, retrofits, timber-frame construction, and DIY projects\u003c\/strong\u003e, where vapour control and reflective performance are required without adding bulk to the build-up.\u003c\/p\u003e\n\u003chr data-end=\"1149\" data-start=\"1146\"\u003e\n\u003ch2 data-end=\"3053\" data-start=\"3019\"\u003e\u003cstrong data-end=\"3053\" data-start=\"3022\"\u003eProduct Dimensions \u0026amp; Weight\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-end=\"3182\" data-start=\"3055\"\u003e\n\u003cli data-end=\"3080\" data-start=\"3055\"\u003e\n\u003cp data-end=\"3080\" data-start=\"3057\"\u003eThickness: \u003cstrong\u003e\u0026lt; 1 mm\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3118\" data-start=\"3081\"\u003e\n\u003cp data-end=\"3118\" data-start=\"3083\"\u003eLength: \u003cstrong\u003e25 m\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3118\" data-start=\"3081\"\u003e\n\u003cp data-end=\"3118\" data-start=\"3083\"\u003eWidth: \u003cstrong\u003e1.5 m\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3182\" data-start=\"3140\"\u003e\n\u003cp data-end=\"3182\" data-start=\"3142\"\u003eWeight: \u003cstrong\u003e4.8 kg\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3182\" data-start=\"3140\"\u003eCoverage:\u003cstrong\u003e 37.5 m²\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1149\" data-start=\"1146\"\u003e\n\u003ch2 data-end=\"1182\" data-start=\"1151\"\u003e\u003cstrong data-end=\"1182\" data-start=\"1154\"\u003e2-in-1 Functional Design\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1253\" data-start=\"1184\"\u003eSuperFOIL SFTV combines two essential functions in a single membrane:\u003c\/p\u003e\n\u003cul data-end=\"1375\" data-start=\"1255\"\u003e\n\u003cli data-end=\"1316\" data-start=\"1255\"\u003e\n\u003cp data-end=\"1316\" data-start=\"1257\"\u003eReflective radiant barrier to improve thermal performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1375\" data-start=\"1317\"\u003e\n\u003cp data-end=\"1375\" data-start=\"1319\"\u003eVapour control layer (VCL) to reduce condensation risk\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1522\" data-start=\"1377\"\u003eThis 2-in-1 design simplifies construction by reducing the need for separate layers while supporting compliance with modern building regulations.\u003c\/p\u003e\n\u003chr data-end=\"1527\" data-start=\"1524\"\u003e\n\u003ch2 data-end=\"1566\" data-start=\"1529\"\u003e\u003cstrong data-end=\"1566\" data-start=\"1532\"\u003eReflective Thermal Performance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"1687\" data-start=\"1568\"\u003eSFTV improves thermal performance by reflecting radiant heat when installed adjacent to an air space, such as a cavity.\u003c\/p\u003e\n\u003cp data-end=\"1734\" data-start=\"1689\"\u003e\u003cstrong data-end=\"1734\" data-start=\"1689\"\u003eCertified thermal performance (EN 16012):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1932\" data-start=\"1736\"\u003e\n\u003cli data-end=\"1761\" data-start=\"1736\"\u003e\n\u003cp data-end=\"1761\" data-start=\"1738\"\u003e\u003cstrong data-end=\"1755\" data-start=\"1738\"\u003eCore R-Value:\u003c\/strong\u003e N\/A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1809\" data-start=\"1762\"\u003e\n\u003cp data-end=\"1809\" data-start=\"1764\"\u003e\u003cstrong data-end=\"1792\" data-start=\"1764\"\u003eRoof (incl. air spaces):\u003c\/strong\u003e \u003cstrong data-end=\"1807\" data-start=\"1793\"\u003e0.90 m²K\/W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1857\" data-start=\"1810\"\u003e\n\u003cp data-end=\"1857\" data-start=\"1812\"\u003e\u003cstrong data-end=\"1840\" data-start=\"1812\"\u003eWall (incl. air spaces):\u003c\/strong\u003e \u003cstrong data-end=\"1855\" data-start=\"1841\"\u003e1.31 m²K\/W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1906\" data-start=\"1858\"\u003e\n\u003cp data-end=\"1906\" data-start=\"1860\"\u003e\u003cstrong data-end=\"1889\" data-start=\"1860\"\u003eFloor (incl. air spaces):\u003c\/strong\u003e \u003cstrong data-end=\"1904\" data-start=\"1890\"\u003e2.62 m²K\/W\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1932\" data-start=\"1907\"\u003e\n\u003cp data-end=\"1932\" data-start=\"1909\"\u003e\u003cstrong data-end=\"1923\" data-start=\"1909\"\u003eEmittance:\u003c\/strong\u003e \u003cstrong data-end=\"1932\" data-start=\"1924\"\u003e0.05\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"2065\" data-start=\"1934\"\u003eThese values demonstrate how SFTV enhances the effectiveness of traditional insulation systems by addressing radiant heat transfer.\u003cstrong data-end=\"1155\" data-start=\"1119\"\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-end=\"2070\" data-start=\"2067\"\u003e\n\u003ch3 data-end=\"2103\" data-start=\"2072\"\u003e\u003cstrong data-end=\"2103\" data-start=\"2076\"\u003eWhat does R-Value mean?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"2231\" data-start=\"2104\"\u003eR-Value (m²K\/W) measures a material’s resistance to heat flow.\u003cbr data-end=\"2169\" data-start=\"2166\"\u003eThe higher the R-Value, the better the insulation performance.\u003c\/p\u003e\n\u003chr data-end=\"2236\" data-start=\"2233\"\u003e\n\u003ch3 data-end=\"2271\" data-start=\"2238\"\u003e\u003cstrong data-end=\"2271\" data-start=\"2242\"\u003eWhat does Emittance mean?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-end=\"254\" data-start=\"188\"\u003e\u003cstrong data-end=\"252\" data-start=\"188\"\u003eEmittance measures how much heat a surface emits (radiates).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-end=\"452\" data-start=\"256\"\u003eA low emittance value (typically around 0.05) means very low heat emission and high reflection of radiant heat, improving overall thermal performance when installed with adjacent air spaces.\u003c\/p\u003e\n\u003cp data-end=\"611\" data-start=\"454\"\u003eThis interpretation is aligned with EN 16012 and reflects how reflective multifoil insulation performance is evaluated across EU technical documentation.\u003c\/p\u003e\n\u003chr data-end=\"2633\" data-start=\"2630\"\u003e\n\u003ch2 data-end=\"1155\" data-start=\"1115\"\u003e\u003cstrong data-end=\"1155\" data-start=\"1119\"\u003eWater Vapour Control Performance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-end=\"1205\" data-start=\"1157\"\u003e\n\u003cli data-end=\"1205\" data-start=\"1157\"\u003e\n\u003cp data-end=\"1205\" data-start=\"1159\"\u003e\u003cstrong data-end=\"1187\" data-start=\"1159\"\u003eWater vapour resistance:\u003c\/strong\u003e \u003cstrong data-end=\"1205\" data-start=\"1188\"\u003e≥ 1200 MN·s\/g\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"1401\" data-start=\"1207\"\u003eThis high vapour resistance helps prevent moisture migration into the building fabric, reducing condensation risk and supporting airtight, energy-efficient construction when installed correctly.\u003c\/p\u003e\n\u003chr data-end=\"2633\" data-start=\"2630\"\u003e\n\u003ch2 data-end=\"2687\" data-start=\"2635\"\u003e\u003cstrong data-end=\"2687\" data-start=\"2638\"\u003ePerformance vs Standard Vapour Control Layers\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"2892\" data-start=\"2689\"\u003eAll SuperFOIL reflective membranes, including SFTV, are \u003cstrong data-end=\"2858\" data-start=\"2745\"\u003etested and certified to deliver almost three times the thermal performance of a standard vapour control layer\u003c\/strong\u003e when installed with an air space.\u003c\/p\u003e\n\u003cp data-end=\"3012\" data-start=\"2894\"\u003eThis significantly reduces condensation risk while improving thermal efficiency in roof, wall, and floor applications.\u003c\/p\u003e\n\u003chr data-end=\"3017\" data-start=\"3014\"\u003e\n\u003ch2 data-end=\"3208\" data-start=\"3189\"\u003e\u003cstrong data-end=\"3208\" data-start=\"3192\"\u003eKey Benefits\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-end=\"3685\" data-start=\"3210\"\u003e\n\u003cli data-end=\"3280\" data-start=\"3210\"\u003e\n\u003cp data-end=\"3280\" data-start=\"3212\"\u003eReflective radiant barrier and vapour control layer in one product\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3334\" data-start=\"3281\"\u003e\n\u003cp data-end=\"3334\" data-start=\"3283\"\u003eUltra-thin profile – ideal where space is limited\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3393\" data-start=\"3335\"\u003e\n\u003cp data-end=\"3393\" data-start=\"3337\"\u003eImproves thermal performance when used with air spaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3428\" data-start=\"3394\"\u003e\n\u003cp data-end=\"3428\" data-start=\"3396\"\u003eHelps reduce condensation risk\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3474\" data-start=\"3429\"\u003e\n\u003cp data-end=\"3474\" data-start=\"3431\"\u003eLightweight, flexible, and easy to handle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3507\" data-start=\"3475\"\u003e\n\u003cp data-end=\"3507\" data-start=\"3477\"\u003eNo specialist tools required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3549\" data-start=\"3508\"\u003e\n\u003cp data-end=\"3549\" data-start=\"3510\"\u003eQuick installation with minimal waste\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3591\" data-start=\"3550\"\u003e\n\u003cp data-end=\"3591\" data-start=\"3552\"\u003eSuitable for roofs, walls, and floors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3641\" data-start=\"3592\"\u003e\n\u003cp data-end=\"3641\" data-start=\"3594\"\u003eSupports compliance with building regulations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3685\" data-start=\"3642\"\u003e\n\u003cp data-end=\"3685\" data-start=\"3644\"\u003eMade using up to 40% recycled materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"3690\" data-start=\"3687\"\u003e\n\u003ch2 data-end=\"3711\" data-start=\"3692\"\u003e\u003cstrong data-end=\"3711\" data-start=\"3695\"\u003eApplications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"3751\" data-start=\"3713\"\u003eSuperFOIL SFTV is suitable for use in:\u003c\/p\u003e\n\u003cul data-end=\"3881\" data-start=\"3753\"\u003e\n\u003cli data-end=\"3775\" data-start=\"3753\"\u003e\n\u003cp data-end=\"3775\" data-start=\"3755\"\u003eRoof constructions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3794\" data-start=\"3776\"\u003e\n\u003cp data-end=\"3794\" data-start=\"3778\"\u003eWall build-ups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3815\" data-start=\"3795\"\u003e\n\u003cp data-end=\"3815\" data-start=\"3797\"\u003eFloor structures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3851\" data-start=\"3816\"\u003e\n\u003cp data-end=\"3851\" data-start=\"3818\"\u003eNew build and retrofit projects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"3881\" data-start=\"3852\"\u003e\n\u003cp data-end=\"3881\" data-start=\"3854\"\u003eTimber-frame construction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"4031\" data-start=\"3883\"\u003eFor best performance, SFTV should be installed adjacent to an air space and sealed using compatible reflective foil tape at joints and penetrations.\u003c\/p\u003e\n\u003chr data-end=\"4036\" data-start=\"4033\"\u003e\n\u003ch2 data-end=\"4070\" data-start=\"4038\"\u003e\u003cstrong data-end=\"4070\" data-start=\"4041\"\u003eFire \u0026amp; Safety Performance\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-end=\"4115\" data-start=\"4072\"\u003e\n\u003cli data-end=\"4115\" data-start=\"4072\"\u003e\n\u003cp data-end=\"4115\" data-start=\"4074\"\u003e\u003cstrong data-end=\"4115\" data-start=\"4074\"\u003eReaction to Fire (Euroclass): Class F\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"4120\" data-start=\"4117\"\u003e\n\u003ch2 data-end=\"4159\" data-start=\"4122\"\u003e\u003cstrong data-end=\"4159\" data-start=\"4125\"\u003eSFTV – Quality \u0026amp; Certification\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-end=\"4485\" data-start=\"4161\"\u003e\n\u003cli data-end=\"4260\" data-start=\"4161\"\u003e\n\u003cp data-end=\"4260\" data-start=\"4163\"\u003eManufactured under a certified \u003cstrong data-end=\"4211\" data-start=\"4194\"\u003eISO 9001:2015\u003c\/strong\u003e quality management system (manufacturer level)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4329\" data-start=\"4261\"\u003e\n\u003cp data-end=\"4329\" data-start=\"4263\"\u003e\u003cstrong data-end=\"4296\" data-start=\"4263\"\u003eCE certified to EN 13984:2013\u003c\/strong\u003e for vapour control performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4412\" data-start=\"4330\"\u003e\n\u003cp data-end=\"4412\" data-start=\"4332\"\u003eTested to meet current UK and EU building regulations when installed correctly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"4485\" data-start=\"4413\"\u003e\n\u003cp data-end=\"4485\" data-start=\"4415\"\u003eDesigned, tested, and supported by \u003cstrong data-end=\"4485\" data-start=\"4450\"\u003eSuperFOIL technical specialists\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"4490\" data-start=\"4487\"\u003e\n\u003ch2 data-end=\"4543\" data-start=\"4492\"\u003e\u003cstrong data-end=\"4543\" data-start=\"4495\"\u003eWhy Choose SuperFOIL SFTV?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"4833\" data-start=\"4545\"\u003eSFTV is specified where \u003cstrong data-end=\"4641\" data-start=\"4569\"\u003evapour control, condensation management, and radiant heat reflection\u003c\/strong\u003e are required as part of a complete insulation build-up. It is commonly used alongside traditional insulation materials to enhance overall thermal efficiency without increasing build-up depth.\u003c\/p\u003e\n\u003cp data-end=\"4944\" data-start=\"4835\"\u003eIts ultra-thin design makes it particularly valuable in retrofit projects and space-restricted constructions.\u003c\/p\u003e\n\u003chr data-end=\"4949\" data-start=\"4946\"\u003e\n\u003ch2 data-start=\"5347\" data-end=\"5407\"\u003e\u003cstrong data-start=\"5350\" data-end=\"5407\"\u003eSuperFOIL SFTV \u0026amp; Recommended Accessories\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1034\/0270\/1149\/files\/SFTV.png?v=1768828615\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1034\/0270\/1149\/files\/KAKO_SE_Z_IZOLACIJO_DELA.png?v=1768818570\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1034\/0270\/1149\/files\/SuperFOIL_recommended_products_NOVA_SLIKA.png?v=1768819179\" width=\"440\" height=\"326\"\u003e\u003c\/p\u003e\n\u003chr data-end=\"4949\" data-start=\"4946\"\u003e\n\u003ch2 data-end=\"4965\" data-start=\"4951\"\u003e\u003cstrong data-end=\"4965\" data-start=\"4954\"\u003eSummary\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-end=\"5291\" data-start=\"4967\"\u003eSuperFOIL SFTV is a high-performance reflective vapour control membrane that improves thermal efficiency and reduces condensation risk in roofs, walls, and floors. With its ultra-thin profile, ease of installation, and certified performance, it is an ideal solution for both professional contractors and informed homeowners.\u003c\/p\u003e","brand":"SuperFOIL","offers":[{"title":"Default Title","offer_id":63141867749725,"sku":null,"price":133.91,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1034\/0270\/1149\/files\/SFTVHEROIMAGE.png?v=1769016211","url":"https:\/\/superfoil.si\/products\/superfoil-sftv","provider":"SuperFOIL Insulation – Official Distributor | Globtrade Ljubljana d.o.o.","version":"1.0","type":"link"}